• VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire
  • VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire
  • VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire
  • VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire
  • VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire
  • VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire

VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire

Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Insulation Material: PVC
Sheath Material: PVC
Material Shape: Round Wire
Customization:

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • Detailed Photos
  • FAQ
Overview

Basic Info.

Model NO.
VLV VLV22
Wire Core Material
Alumnium
Certification
ISO, CCC, CE, RoHS, VDE
Model
VV/Vlv/VV22/VV32
Brand
Zhaoxin
Customize
Ok
Transport Package
Wooden Box Packing or Pallet Shipping Containers
Specification
φ 1500× φ 650× 1100mm
Trademark
Zhaoxin
Origin
Hebei, China
Production Capacity
50000m/Week

Product Description

Product Description

VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable electric wire

1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.

2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.

3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.

4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty

5.Light weight,good bending property and easy installation and maintenance.


Structure 

VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire
VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire

 

Standards
The products can be produced in accordance with GB, IEC, BS, and other standards.

 Basic Information
Model No: VV/VLV/VV22/VV32
Material Shape: Round Wire
Certificate: ISO9001,ISO14001, CCC, CE        
Origin: Hebei, China.
Voltage: 0.6/1kv
Current: AC & DC
Insulation Material: PVC
Sheath Material:PVC
Material Shape: Round wire


Application
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
 

Product Parameters
Executive Standard:ASTM          
    Bare neutral Messenger Phase conductor            
Code Word AWG or kcmil AAAC Rated Strength AAC insulation thickness (m m ) Weight (kg/km )          
    s trading and w ires dia(mm ) (lbs ) strading and wires dia(mm )            
Bay 3*6AWG+ 1*30.58 7/ 1.68 1110 1/4.11 1.14 207          
French Coach 3*6AWG+ 1*30.58 7/ 1.68 1110 7/ 1.56 1.14 2 13          
German Coach 3*4AWG+ 1*48.69 7/2. 12 1760 1/5.1 9 1.14 309          
Arabian 3*4AWG+ 1*48.69 7/2. 12 1760 7/ 1.96 1.14 316          
Belgian 3*2AWG+ 1*77.47 7/2.67 2800 7/2.47 1.14 476          
Shet land 3*1/0AWG+ 1*123.3 7/3.37 4460 19/ 1.89 1.52 768          
Thoroughbred 3*2/0AWG+ 1*155.4 7/3.78 5390 19/2.13 1.52 945          
Trotter 3*2/0AWG+ 1*195.7 7/4.25 6790 19/2.39 1.52 1166          
Walking 3*4/0AWG+ 1*246.9 7/4.77 8560 19/2.68 1.52 1442          
                       
Executive Standard:NFC        
                       
  Nom inal     Average diameter of   Average                  insulation thickness        
  cross-section aera Wire number in Conductor Max resistance at 20 conductor Rated Strength        
Description mm 2 No. Ohm /k m Min(m m ) Max(m m ) KN m m        
PHASE, NEUTRAL,and PUBLIC HIGHTING 16 7 1.91 4.6 5.1 1.9 1.2        
25 7 1.2 5.8 6.3   1.4        
35 7 0.868 6.8 7.3   1.6        
50 7 0.641 7.9 8.4   1.6        
70 12 0.443 9.7 10.2   1.8        
95 19 0.32 11 12   1.8        
120 19 0.253 12 13.1   1.8        
150 19 0.206 13.9 15   1.7        
PORTER 54.6 7 0.63 9.2 9.6   1.6        
70 7 0.5 10 10.2   1.5        
95 19 0.343 12.2 12.9 27.5 1.6        
                       
Executive Standard:IEC1        
Phase Phase Phase   Max. D.C.        
AAC+UV-XLPE Compact Conductor UV-XLPE Insulation Approx.Overall Diam eter Res is tance of Conductor at 20ºC        
No.X Norm al Cross Section of Cores No.of Al Wires Overall Diameter Normal Thickness Min. Diameter            
No. X m m 2 - m m m m m m m m m m ohm /k m        
1 X 10 7/1.35 4.05 1 0.8 6.05 6.05 3.08        
1 X 16 7/1.70 4.8 1.2 0.98 7.2 7.2 1.91        
1 X 25 7/2.24 6 1.2 0.98 8.4 8.4 1.2        
1 X 35 7/2.58 7 1.4 1.16 9.8 9.8 0.868        
1 X 50 7/3.00 8.3 1.4 1.16 11.1 11.1 0.641        
1 X 70 19/2.15 9.8 1.4 1.16 12.6 12.6 0.443        
1 X 95 19/2.58 11.6 1.6 1.34 14.8 14.8 0.32        
1 X 120 18/3.00 13 1.6 1.34 16.2 16.2 0.253        
1 X 150 30/2.58 14.6 1.8 1.52 18.2 18.2 0.206        
1 X 185 36/2.58 16.2 2 1.7 20.2 20.2 0.164        
1 X 240 36/3.00 18.4 2.2 1.88 22.8 22.8 0.125        
2 X 10 7/1.35 4.05 1 0.8 6.05 12.1 3.08        
2 X 16 7/1.70 4.8 1.2 0.98 7.2 14.4 1.91        
2 X 25 7/2.24 6 1.2 0.98 8.4 16.8 1.2        
2 X 35 7/2.58 7 1.4 1.16 9.8 19.6 0.868        
2 X 50 7/3.00 8.3 1.4 1.16 11.1 22.2 0.641        
2 X 70 19/2.15 9.8 1.4 1.16 12.6 25.2 0.443        
2 X 95 19/2.58 11.6 1.6 1.34 14.8 29.6 0.32        
2 X 120 18/3.00 13 1.6 1.34 16.2 32.4 0.253        
2 X 150 30/2.58 14.6 1.8 1.52 18.2 36.4 0.206        
2 X 185 36/2.58 16.2 2 1.7 20.2 40.4 0.164        
2 X 240 36/3.00 18.4 2.2 1.88 22.8 45.6 0.125        
3 X 10 7/1.35 4.05 1 0.8 6.05 13.07 3.08        
3 X 16 7/1.70 4.8 1.2 0.98 7.2 15.55 1.91        
3 X 25 7/2.24 6 1.2 0.98 8.4 18.14 1.2        
3 X 35 7/2.58 7 1.4 1.16 9.8 21.17 0.868        
3 X 50 7/3.00 8.3 1.4 1.16 11.1 23.98 0.641        
3 X 70 19/2.15 9.8 1.4 1.16 12.6 27.22 0.443        
3 X 95 19/2.58 11.6 1.6 1.34 14.8 31.97 0.32        
3 X 120 18/3.00 13 1.6 1.34 16.2 34.99 0.253        
3 X 150 30/2.58 14.6 1.8 1.52 18.2 39.31 0.206        
3 X 185 36/2.58 16.2 2 1.7 20.2 43.63 0.164        
3 X 240 36/3.00 18.4 2.2 1.88 22.8 49.25 0.125        
4 X 10 7/1.35 4.05 1 0.8 6.05 14.64 3.08        
4 X 16 7/1.70 4.8 1.2 0.98 7.2 17.42 1.91        
4 X 25 7/2.24 6 1.2 0.98 8.4 20.33 1.2        
4 X 35 7/2.58 7 1.4 1.16 9.8 23.72 0.868        
4 X 50 7/3.00 8.3 1.4 1.16 11.1 26.86 0.641        
4 X 70 19/2.15 9.8 1.4 1.16 12.6 30.49 0.443        
4 X 95 19/2.58 11.6 1.6 1.34 14.8 35.82 0.32        
4 X 120 18/3.00 13 1.6 1.34 16.2 39.2 0.253        
4 X 150 30/2.58 14.6 1.8 1.52 18.2 44.04 0.206        
4 X 185 36/2.58 16.2 2 1.7 20.2 48.88 0.164        
4 X 240 36/3.00 18.4 2.2 1.88 22.8 55.18 0.125        
                       
Executive Standard:IEC2      
Phase Neutral Phase Neutral   Max. D.C.    
AAC+UV-XLPE AAAC Compact Conductor UV-XLPE Ins ulation Conductor   Resistance of Conductor at 20ºC    
No.X Norm al Cr os s No.X Norm al Cross           Approx. Overall Diam eter        
Section of Cores Section of Cores No.of Al.Wire Overall Dia. Norm al Thick ness Min. No./Dia. of Al Alloy Wire   Phase Neutral    
No. X m m 2 No. X m m 2 - m m m m Min. No./m m m m ohm /k m ohm /k m    
1 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 12.3 1.91 2.217    
1 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 14.7 1.2 1.393    
1 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 17.3 0.868 1.007    
1 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 20.1 0.641 0.744    
1 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 23.1 0.443 0.514    
1 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 27.3 0.32 0.371    
1 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 30.2 0.253 0.294    
1 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 33.95 0.206 0.239    
1 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 37.7 0.164 0.19    
1 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 43.05 0.125 0.145    
2 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 14.04 1.91 2.217    
2 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 16.63 1.2 1.393    
2 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 19.51 0.868 1.007    
2 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 22.46 0.641 0.744    
2 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 25.7 0.443 0.514    
2 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 30.31 0.32 0.371    
2 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 33.41 0.253 0.294    
2 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 37.55 0.206 0.239    
2 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 41.69 0.164 0.19    
2 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 47.41 0.125 0.145    
3 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 16.15 1.91 2.217    
3 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 19.06 1.2 1.393    
3 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 22.32 0.868 1.007    
3 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 25.59 0.641 0.744    
3 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 29.22 0.443 0.514    
3 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 34.42 0.32 0.371    
3 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 37.87 0.253 0.294    
3 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 42.56 0.206 0.239    
3 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 47.25 0.164 0.19    
3 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 53.63 0.125 0.145    
                       
Executive Standard:IEC3                      
Phase Neutral Service Connection Phase Neutral Service Connection  
Approx. Overall
Diameter of Bundled Cable
AAC+UV-XLPE AAAC+UV-XLPE AAC+UV-XLPE Conductor UV-XLPE Conductor UV-XLPE Compact Conductor UV-XLPE  
No.X Normal Cross No.X Normal Cross No.X Normal Cross     Normal   Normal     Normal  
Section of Cores Section of Cores Section of Cores No. of Al. Wire Overall Dia. No./Dia. of Al. Wire No. of Al. Wire Overall Dia.
                       
Thickness Thickness Thickness
No. X mm2 No. X mm2 No. X mm2 - mm mm mm mm No./mm mm mm mm
3 X 16 1 X 50 1 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 1 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 1 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 1 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 1 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 1 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 1 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2
3 X 16 1 X 50 2 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 2 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 2 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 2 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 2 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 2 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 2 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2
Company Profile

VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric WireVV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire

Packaging & Shipping

VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire

VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire
VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire
Detailed Photos

VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric WireVV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric WireVV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire

Our Customer

VV Vlv Yjv Yjlv Low Voltage 400mm Electric Power Cable Electric Wire

FAQ

1.Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last. 
Welcome to visit us. We'll pick you up in Beijing or Shijiazhuang Airport.

2. How can I get a sample to test your quality?
The samples are free, Customers should pay for the courier. Courier charge can be deducted from your order amount.

 3. What's your Minimum Order Quantity?
MOQ: 100meter. 

4. Can I get a discount?
Discount can be negotiated when we talked about the order. Anyway we will try our best to provide you the best quality with better price and best shipping rate.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
3000000 RMB
Plant Area
501~1000 square meters